Vmware Nsx 6.0
VMware NSX for v. Sphere 6. 3. 0 Release Notes VMware NSX for v. Sphere 6. 3. 0 Released 2 February 2. Build 5. 00. 70. 49 Whats in the Release Notes. The release notes cover the following topics Whats New. New features in NSX 6. Step5e_605.png' alt='Vmware Nsx 6.0' title='Vmware Nsx 6.0' />Platform and Compliance Features On the Platform side Cross v. Center NSX Active Standby DFW Enhancements NSX 6. Multiple Universal DFW sections are now supported. Both Universal and Local rules can consume Universal security groups in Source, Destination, and Applied. To fields. Universal Security Groups Universal Security Group membership can be defined in a static or dynamic manner. Static membership is achieved by manually adding a universal security tag to each VM. Dynamic membership is achieved by adding VMs as members based on dynamic criteria VM name. Universal Security Tags You can now define Universal Security tags on the primary NSX Manager and mark for universal synchronization with secondary NSX Managers. Universal Security tags can be assigned to VMs statically, based on unique ID selection, or dynamically, in response to criteria such as antivirus or vulnerability scans. Unique ID Selection Criteria In earlier releases of NSX, security tags are local to a NSX Manager, and are mapped to VMs using the VMs managed object ID. In an active standby environment, the managed object ID for a given VM might not be the same in the active and standby datacenters. NSX 6. 3. x allows you to configure a Unique ID Selection Criteria on the primary NSX Manager to use to identify VMs when attaching to universal security tags VM instance UUID, VM BIOS UUID, VM name, or a combination of these options. See Unique ID Selection in the NSX Administration Guide for more information. Due to frozen the ESXi 6. Management agent services by the following command by reference of. VMware, a global leader in cloud infrastructure digital workspace technology, accelerates digital transformation for evolving IT environments. Learn More Now. This site explains the key differences between vSphere 6. Sphere 6. 5. An overview comparison from all vSphere Versions is available here. VMware NSX is the SDDC technology of the future. What ESX was once for Servers, NSX is now for Networks. I highly encourage everyone to make yourselves familiar with. Control Plane Agent netcpa Auto recovery An enhanced auto recovery mechanism for the netcpa process ensures continuous data path communication. The automatic netcpa monitoring process also auto restarts in case of any problems and provides alerts through the syslog server. A summary of benefits automatic netcpa process monitoring process auto restart in case of problems, for example, if the system hangs automatic core file generation for debugging alert via syslog of the automatic restart event v. Sphere 6. 5 Compatibility NSX 6. Sphere 6. 5a and later. NSX 6. 3. 0 retains compatibility with v. Vmware Nsx 6.0' title='Vmware Nsx 6.0' />Sphere 5. Tech Preview Controller Disconnected Operation CDO mode Controller Disconnected Operation CDO mode has been introduced as a tech preview feature. This mode ensures that data plane connectivity is unaffected when hosts lose connectivity with the controller. See the section Controller Disconnected Operation CDO Mode in the NSX Administration Guide. See also Issue 1. Compliance features FIPS NSX 6. FIPS mode that uses only those cipher suites that comply with FIPS. Vmware Nsx 6.0' title='Vmware Nsx 6.0' />Its been long time, i am thinking to post about VMware NSX. Lets start from this post. I am so impressed with VMware NSX. Lets discuss in detail about Step by step. Vmware Nsx 6.0' title='Vmware Nsx 6.0' />NSX Manager and NSX Edge have a FIPS Mode that can be enabled via the v. Sphere Web Client or the NSX REST API. See Functionality Difference Between FIPS Mode And Non FIPS Mode in the NSX Administration Guide for a list of functionality affected by FIPS mode. Note VMware development partners are undergoing certification of new, FIPS compliant partner solutions for use in NSX. NSX 6. 3. 0 outbound connections are TLS 1. FIPS approved cipher suites. This means partner appliances that receive callbacks must configure secure web listeners to more secure cipher suites. The following lists the Default mode and FIPS mode ciphers Default Mode ciphers FIPS mode OFF TLSECDHEECDSAWITHAES2. CBCSHA3. 84, TLSECDHERSAWITHAES2. CBCSHA3. 84, TLSRSAWITHAES2. New Horizons can help you distinguish yourself in the market with VMware training and certification. Enroll today and advance your skills. NSX Installation and Upgrade Guide Overview of NSX NSX Components Data Plane Control Plane Management Plane Consumption Platform. CBCSHA2. 56, TLSECDHECDSAWITHAES2. CBCSHA3. 84, TLSECDHRSAWITHAES2. CBCSHA3. 84, TLSDHERSAWITHAES2. CBCSHA2. 56, TLSDHEDSSWITHAES2. CBCSHA2. 56, TLSECDHEECDSAWITHAES2. CBCSHA, TLSECDHERSAWITHAES2. CBCSHA, TLSRSAWITHAES2. CBCSHA, TLSECDHECDSAWITHAES2. CBCSHA, TLSECDHRSAWITHAES2. CBCSHA, TLSDHERSAWITHAES2. CBCSHA, TLSDHEDSSWITHAES2. CBCSHA, TLSECDHEECDSAWITHAES1. CBCSHA2. 56, TLSECDHERSAWITHAES1. CBCSHA2. 56, TLSRSAWITHAES1. CBCSHA2. 56, TLSECDHECDSAWITHAES1. Wireshark Win32 1 7 0 Exe. CBCSHA2. 56, TLSECDHRSAWITHAES1. CBCSHA2. 56, TLSDHERSAWITHAES1. CBCSHA2. 56, TLSDHEDSSWITHAES1. CBCSHA2. 56, TLSECDHEECDSAWITHAES1. CBCSHA, TLSECDHERSAWITHAES1. CBCSHA, TLSRSAWITHAES1. CBCSHA, TLSECDHECDSAWITHAES1. CBCSHA, TLSECDHRSAWITHAES1. CBCSHA, TLSDHERSAWITHAES1. CBCSHA, TLSDHEDSSWITHAES1. CBCSHA, TLSECDHEECDSAWITH3. DESEDECBCSHA, TLSECDHERSAWITH3. DESEDECBCSHA, SSLRSAWITH3. DESEDECBCSHA, TLSECDHECDSAWITH3. DESEDECBCSHA, TLSECDHRSAWITH3. DESEDECBCSHA, SSLDHERSAWITH3. DESEDECBCSHA, SSLDHEDSSWITH3. DESEDECBCSHA, TLSEMPTYRENEGOTIATIONINFOSCSV FIPS mode ciphers TLSRSAWITHAES2. CBCSHA2. 56, TLSRSAWITHAES1. CBCSHA2. 56, TLSRSAWITHAES2. CBCSHA, TLSRSAWITHAES1. CBCSHA Both Default and FIPS modes support TLS 1. See the VMware Compatibility Guide to verify whether partner solutions are FIPS mode certified. Common Criteria For Common Criteria compliance, NSX has been tested for compliance with the EAL2 level of assurance. Running a Common Criteria compliant NSX installation requires that you configure NSX as explained in the document Configuring NSX for Common Criteria. NSX Administration Guide. ICSA This is an industry wide accepted standard certification which tests and certifies products including anti virus, firewall, IPSec VPN, cryptography, SSL VPN, network IPS, anti spyware, and PC firewall products. Both Distributed Firewall and Edge Firewall are certified against ICSA Corporate Firewall criteria. Change in DFW packet log format due to ICSA certification requirement NSX 6. DFW packet logs. In 6. ICMP type and code to satisfy ICSA certification requirements. This is how the pre 6. ICMP code and type 2. T2. 0 5. 2 2. 1. Z 6. INET6 match PASS domain c. IN 9. 6 ICMP fe. 80 0 0 0 2. In 6. 3. 0 and later, it looks like the following with ICMP code and type. In this example, 8 is the code and 0 is the type 2. T2. 0 5. 4 1. 6. Z 4. INET match PASS domain c. IN 8. 4 ICMP 8 0 1. Operations Enhancements. Troubleshooting Dashboard NSX Dashboard is updated in NSX 6. NSX Manager backup status, and Edge Appliance notifications. Security Tagging This allows assigning and clearing multiple tags for a given VM through API calls. Syslog Enhancements A new syslog update is available specifically for Load Balancer. Log Insight Content Pack This has been updated for Load Balancer to provide a centralized Dashboard, end to end monitoring, and better capacity planning from the user interface UI. Role Based Access Control This feature restricts user management only to Enterprise Administrators, and as a result, the NSX Administrator will no longer have permission to create new users or assign roles to new users. From a security standpoint, this helps in creating a clear demarcation of these two admin roles. Drain state for Load Balancer pool members You can now put a pool member into Drain state, which forces the server to shutdown gracefully for maintenance. Setting a pool member to drain state removes the backend server from load balancing, but still allows the server to accept new, persistent connections. Service and Routing Enhancements 4 byte ASN support for BGP BGP configuration with 4 byte ASN support is made available along with backward compatibility for the pre existing 2 byte ASN BGP peers.